Engine power range from 3 to 35 Hp
LME - LMEK series
Bell-Housings
Bell-Housing
113
Introduction
10
Bell-Housings & Couplings sizing
Power Transmission
AUTOMATIC
MANUALLY
11
12
p.
BELL-HOUSINGS
& COUPLINGS
SOFTWARE FOR AUTOMATIC CALCULATION
Scan or click me!
The web-based software program will allow you to select the most suitable
MP Filtri’s Filters, in accordance with your process design requirements.
The program will automatically check your input design process prior to propose
you the acceptable solutions and create an output in PDF report style format.
The MP Filtri Selection Tool software program is easy to use with a exible fast
design method and provides improved layout formats with full descriptions.
The web-based tool is available at MP Filtri website at following link:
https://www.mpltri.com/tools/
The related, complete user guide is available as Manual and downloadable from
the “Download” section of MP Filtri website, as well as scanning the following
QR code
Introduction
11
BELL-HOUSINGS & COUPLINGS SIZING
A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING MANUALLY
Pages 75 ÷ 81 for IEC Electric motor size 100-112 - LMC250
LMC 250 bell-housing with height ≥ 135.5 - LMC250AFSQ
The bell-housing code must be completed with pump drilling code (see pages 60-61).
For the specic case:
Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
Denitive bell-housing code LMC250AFSQ060
Pages 83 ÷ 89 for IEC Electric motor size 100-112 - LMS250
LMS 250 bell-housing with height ≥ 135.5 - LMS250AFSA
The bell-housing code must be completed with pump drilling code (see pages 60-61).
For the specic case:
Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
Denitive bell-housing code LMS250AFSA060
Bell-Housing’s length calculation
Case A
Solution with monobloc bell-housing series LMC/LDC
Case B
Solution with low noise bell-housing series LMS/LDS
- H = 60 + 18 + 57.5 = 135.5 mm (18 = Sp spider - see page 31)
- Choose type of bell-housing (LMC - LMS):
For monobloc bell-housing LMC/LDC series see pages 75 ÷ 81
For Low noise bell-housing LMS/LDS series see pages 81 ÷ 89
For Multi-components 2-3 bell housing series see pages 91 ÷ 111
Note:
The length of bell-housing must be ≥ than the length calculated (135.5 mm)
- Electric motor power/motor size
- Manufacturer and pump type
1 - Pump and motor shaft dimensions (see electric motor data sheet)
2 - Shaft and ange pump (see pump data sheet)
Example:
- Electric motor 2.2 kW - size 100-112
- Atos pump code PFE31 - Shaft 1
DATA REQUIRED
TO VERIFY:
IEC Electric motor dimension Hydraulic pump dimension
Ø28 - key 8
Ø19.05 - key 4.76
Ø250
60
57.5
9.5
Ø82.55
Ø106.4
Nr. 2 Ø11
code M05 see page 18
code G01 see page 18
Introduction
12
BELL-HOUSINGS & COUPLINGS SIZING
A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING MANUALLY
Motor half-coupling (see page 26)
For IEC Electric motor size 100/112, the half-coupling is SGEA21M05060
Spider (see page 31)
For SGEA21, EGE2 - EGE2RR
(choose spider material on the base of the application, oil, temperature and cycle machine, etc.)
Pump half-coupling
Choose the drilling code - see pages 18-19 for shaft 19.05 - key 4.76 - code: G01
Pump half-coupling length = BH length - THK Spider - THK Spigot
LMC = 138 mm - 60 - 18 - 9.5 = 50.5 mm
LMS = 148 mm - 60 - 18 - 9.5 = 60.5 mm
LMC - Choose the half-coupling’s length at page 26 ≤ 50.5 mm.
LMS - Choose the half-coupling’s length at page 26 ≤ 60.5 mm.
LMC - Available length for SGEA21 = 50 mm
LMS - Available length for SGEA21 = 60 mm
Half coupling for LMC: SGEA21G01050
Half coupling for LMS: SGEA21G01050
Coupling selection
Note: for multi pumps we recommend to use a specic support on the base of the pump’s dimensions and weight.
Introduction
13
GENERAL INFORMATION NOISE
THEORY AND DEFINITION OF NOISE
From a health and hygiene standpoint, noise can be dened as an unpleasant
and undesirable sound, or an unpleasant and annoying or intolerable auditory
sensation (noise being any sound phenomena that may be accompanied by
sensations of disturbance and pain). By definition, acoustic phenomena are
oscillatory in character, propagated in a exible medium and causing pressure
variations at the points, and the areas adjacent to those points, through which
they pass.
2
1
SOUND
Technically considered, certain elements must be present simultaneously
for acoustic phenomena to occur:
- Sound source
- Transmission medium
- Receive
The electric motor and the pump, together with the drive coupling, are the
SOURCE OF THE NOISE. The Bell-housing is the noise transmission MEDIUM.
Depending on whether the monobloc bell-housing is a rigid or low noise type,
there will be variations in the exible properties of the transmission medium.
The acoustic phenomena are dissimilar in the two cases, given the differences in
pressure variation and particle displacement.
MOTOR AND PUMP UNIT
Noise is a particularly pervasive problem so much so that there have been statutory regulations in place now for some years, designed to limit harmful
occupational exposure.
Many of the machines used in industry today are equipped with oil-hydraulic systems, which happen to be a major source of noise.
RECEIVER
- Human ear
- Sound level meter
BELL-HOUSING
ELECTRIC MOTOR
PUMP
Bell-Housing
58
ASSEMBLY OF MOTOR AND PUMP UNIT
Low noise bell-housing will help to attenuate the transmission of vibrations and the emission of noise generated by the system.
Self-evidently, however, the mere adoption of a low noise bell-housing will achieve little unless the motor and pump are correctly installed on the machine
or on the tank of the hydraulic power unit.
Should be followed in order to achieve best possible results and correct installation:
1
MOTOR AND PUMP UNIT MOUNTED
HORIZONTALLY ON OIL TANK LID
- The suction pipe attached to the pump must be rigid and tted using a resilient
bulkhead flange of the FTA series, which helps to cushion the vibrations
propagated between the pipe and the tank lid.
If pipes need to be bent, the radius of curvature must be at least 3 times the
pipe diameter.
Do not use elbow ttings, as these will signicantly increase pressure losses.
- The pressure pipeline of the pump must be flexible and long enough to
include bends with the minimum radius of curvature recommended by the
manufacturer for the specied operating pressure.
- The return pipeline running from the service to the lter must be exible.
Where oil is returned directly to the tank of the hydraulic power unit through
a rigid pipe, it is advisable to use a resilient bulkhead ange of the FTR series,
which helps to cushion the vibrations propagated between the pipe and
the tank lid.
- Anti-vibration devices (resilient mounts or damping rods) must be located
under the feet of the electric motor or the PDM foot brackets, depending on
the mounting position of the motor.
- The lids of hydraulic oil tanks must be sturdy enough to support the load
they carry.
2
MOTOR AND PUMP UNIT MOUNTED
HORIZONTALLY ON MACHINE
- As a matter of good practice, the oil tank and motor-pump unit should be
mounted on a single supporting frame of strength sufcient to support the load.
- If the hydraulic system is tted with a side-mounted lter, the suction pipeline
to the pump must be flexible and long enough to include bends with the
minimum radius of curvature recommended by the manufacturer.
- If the suction filter is not side mounted, the pipeline should be rigid and
installed in conjunction with a compensating coupling.
- The pressure pipeline of the pump must be exible, and long enough to include
bends with the minimum radius of curvature recommended by the manufacturer
for the specied operating pressure.
- The return pipeline running from the service to the lter must be exible.
Where oil is returned directly to the tank of the hydraulic power unit through
a rigid pipe, it is advisable to use a resilient bulkhead ange of the FTR series,
which helps to cushion the vibrations propagated between the pipe
and the tank lid.
- Anti-vibration devices (resilient mounts or damping rods) must be located
under the feet of the electric motor or the PDM foot brackets, depending
on the mounting position of the motor.
FINAL CONSIDERATION
For best results, in any event, the motor-and-pump unit should be incorporated into the hydraulic system in such a way that no one component is rigidly associated
with another, resulting in the propagation of vibration, and consequently noise.
RECOMMENDED TIGHTENING TORQUES FOR MOTOR/PUMP FIXING ON THE BELL-HOUSING
M6
M8
M10
M12
M14
M16
M18
M20
M22
M24
10 N∙m
15 N∙m
50 N∙m
84 N∙m
135 N∙m
205 N∙m
280 N∙m
400 N∙m
530 N∙m
690 N∙m
Note: The above guidelines are indicative only and subordinate to the solutions adopted ultimately by design engineers.
Bell-Housing
59
PCD
40
45.2
50
50.8
56
57.15
60
62.7
63
65
70
71.8
75
80
82.55
85
90
92
72.00
88.90
71.80
80.00
93.00
60.00
63.00
93.00
82.50
76.00
106.40
74.00
98.50
75.00
157.20
100.00
125.00
85.00
80.00
80.00
100.00
82.00
90.00
90.00
84.00
88.90
102.00
100.00
103.20
100.00
100.00
110.00
140.00
115.00
100.00
106.40
130.00
100.00
113.00
95.00
103.00
110.00
106.40
105.00
106.40
146.00
110.00
106.40
112.00
105.00
118.00
112.00
140.00
145.00
2
4
4
2
2
4
4
2
2
4
2
4
4
4
4
2
4
4
2
4
2
4
4
4
4
4
4
4
2
4
2
2
2
2
4
2
4
4
4
4
4
4
2
4
2
2
2
2
2
4
2
2
4
4
191
096
120
052
053
280
057
287
050
234
212
098
147
227
231
042
043
044
051
058
062
168
271
073
289
047
139
024
045
059
061
063
064
065
067
083
087
093
104
169
242
272
060
097
254
260
284
066
134
156
163
164
088
089
Nr. holes Code
Spigot hole
[mm]
Type
GENERAL INFORMATION
Bell-housing with nr. 2 holes
at pump interface, aligned
with through holes at motor
interface.
Valid conguration
for bell-housing up to Ø400
Valid conguration for bell-housing
from Ø450 to Ø660
Bell-housing with nr. 4 holes at
pump interface, aligned with
thread holes at motor interface.
Bell-housing with nr. 2 holes
at pump interface + 22.5°
compared to through holes at
motor interface.
Bell-housing with nr. 4 holes
at pump interface + 22.5°
compared to thread holes at
motor interface.
-”: conguration out of ISO & SAE Standard
Ø Ø Ø Ø
Spigot
hole
Spigot
hole
Spigot
hole
Spigot
hole
PCDPCDPCDPCD
PUMP INTERFACE CODES
-
-
-
ISO3019-2-50-B2
-
-
-
-
SAE A-A 50-2
-
-
-
-
-
-
ISO3019-2-63-B2
-
-
-
-
-
ISO3019-2-63-B4
-
-
-
-
-
ISO3019-2-80-B4
ISO3019-2-80-B2
-
-
-
-
-
-
-
-
-
-
-
-
-
SAE A 82-2
-
-
-
-
-
-
-
-
-
-
-
M8
M8
M8
M8
M10
M5
ø7
M8
M8
M6
ø11
M10
M6
M6
M12
M8
M6
M8
M8
ø8.5
M10
M8
M8
M8
ø7
M10
M10
M8
M8
ø11
M10
M10
M10
M10
M10
M10
M8
ø8.5
M12
M8
M8
M10
M10
M10
M8
M12
M10
M10
M8
M8
ø9
ø9
M8
M10
Ø
Bell-Housing
60
PCD
95
98.4
100
101.6
105
110
112
115
116
120
125
127
130
115.00
127.00
125.00
125.00
125.00
125.00
125.00
190.00
125.00
125.00
140.00
146.00
126.00
120.00
160.00
150.00
161.50
146.00
127.00
146.00
127.00
146.00
175.00
130.00
200.00
135.00
145.00
140.00
140.00
130.00
180.00
160.00
210.00
145.00
150.00
160.00
160.00
160.00
180.00
155.00
160.00
200.00
181.20
200.00
180.00
170.00
161.50
181.20
161.50
165.00
150.00
181.20
165.00
165.00
4
4
4
2
4
4
4
4
4
2
2
2
2
4
4
4
4
2
4
2
4
2
4
4
4
4
4
2
2
4
4
2
2
4
4
4
4
2
2
4
4
4
2
4
4
4
4
2
4
4
4
2
4
4
137
131
128
023
025
031
032
038
041
071
072
075
106
122
141
150
029
070
125
159
224
076
110
154
202
219
273
074
138
264
198
084
094
155
267
026
033
079
082
102
113
114
136
200
215
237
021
080
140
054
068
085
124
135
Nr. holes Code
Spigot hole
[mm]
Type Type
PCD
130
135
140
150
152.4
160
162
165.1
175
177.8
180
200
203.2
205
224
250
275
165.00
160.00
175.40
180.00
180.00
165.00
200.00
165.00
180.00
185.00
228.60
228.60
228.60
217.50
228.60
228.60
190.50
200.00
200.00
200.00
224.00
200.00
230.00
185.00
224.00
230.00
188.00
317.35
317.35
229.00
317.35
200.00
230.00
350.00
216.00
350.00
216.00
216.00
224.00
216.00
215.00
230.00
250.00
250.00
280.00
230.50
254.00
240.00
280.00
280.00
310.00
315.00
355.00
355.00
4
4
4
4
2
4
4
4
2
4
4
2
4
4
2
4
4
4
4
2
2
2
4
4
4
4
4
4
2
4
4
4
2
4
4
2
4
4
4
4
4
4
4
4
2
4
4
4
4
4
4
4
4
4
253
151
220
077
081
157
176
223
232
069
022
090
108
118
166
192
207
027
035
091
092
107
111
152
184
228
263
143
145
201
204
153
185
146
222
203
055
078
112
132
148
226
028
095
117
214
210
133
144
205
238
282
233
281
Nr. holes Code
Spigot hole
[mm]
GENERAL INFORMATION
-”: conguration out of ISO & SAE Standard -”: conguration out of ISO & SAE Standard
PUMP INTERFACE CODES
-
-
-
ISO3019-2-100-B4
ISO3019-2-100-B2
-
-
-
-
-
-
-
-
-
-
-
-
SAE B 101-2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ISO3019-2-125-B4
-
-
ISO3019-2-125-B2
-
-
-
-
-
-
-
-
SAE C 127-2
-
-
-
-
-
-
-
-
-
ISO3019-2-140-B4
-
-
ISO3019-2-140-B2
-
-
-
-
-
-
-
SAE D 152-2
SAE D 152 -4
-
ISO3019 - 2 -160 B4
-
-
ISO3019 - 2 -160 B2
-
-
-
-
-
-
SAE E 165 - 4
SAE E 165 - 2
-
-
-
-
SAE F 177 - 4
-
SAE F 177 - 2
-
-
ISO3019 - 2 -180 B4
-
-
-
ISO3019 - 2 -200 B4
-
-
-
-
-
ISO3019 - 2 -224 B4
-
-
ISO3019 - 2 -250 B4
-
-
M8
M10
ø11
M10
M10
ø11
M5
ø15
ø13
M12
M12
M12
M10
M8
M10
M10
M12
M12
M12
M10
M10
M12
M10
M8
M10
M10
M12
M12
M10
M10
M12
M14
M16
M10
ø13
M12
ø13
M12
M16
M10
ø17
M12
M16
M16
ø20
ø18
M12
M16
M14
ø11
M12
M16
M12
M14
M10
M10
M12
M14
M12
M10
M16
ø11
M16
M16
M16
M18
M18
ø17
M20
M20
M8
M16
ø17
M16
M20
M12
M22
M12
M16
ø22
M12
M20
M24
M20
M18
M12
M18
M24
M12
M24
ø13
M16
M16
M12
M22
M22
M20
ø22
M24
M12
M14
M16
M20
ø22
M24
M20
M16
ø18
Ø Ø
Bell-Housing
61
- Bell-housing: Pressure die casting Aluminium
- Couplings: Steel NBR 75 Shore A
- Gasket: Special paper - Guarnital
Versions:
- Single-drilled bell-housing for pump group 1 or 2, with pump centering ring
included (see pages 116-117).
- Bell-housing with Multi -Drilling machined for pump group 1 and 2,
with pump centering ring to be ordered separately (see page 118).
- Bell-Housing for Kubota engines and pump group 1 or 2, ZF, Bosch SAE A 2 BOLT,
SAE B 2 BOLT and SAE C 2 BOLT.
- Available for:
serie Super Mini Z482 - Z602 - D722 - D902
serie 05 D1105 - D1305 - V1505
Materials
Bell-housing - Engine power range from 3 to 35 Hp
LME - LMEK GENERAL INFORMATION
Technical data
Bell-housing components compatible for use with:
- Mineral oils types HH-HL-HM-HR-HV, to ISO 6743/4 standard
- Water based emulsions types HFAE-HFAS, to ISO 6743/4 standard
- Water glycol type HFC, to ISO 6743/4 standard: ask for anodized version
Compatibility with uids
Any applications not covered by the normal indications contained in this
catalogue must be evaluated and approved by MP Filtri Technical and Sales
Department.
In order to ensure maximum reliability of the application, internal combustion
engines up to 13.5 kW require the exclusive use of aluminium couplings and
95 Shore A polyurethane elastic inserts (see page 120).
For Kubota 05 series and super mini series engines, steel couplings with
vulcanised rubber must be used.
Special Applications
From -30 °C to +80 °C
Temperature
For temperatures outside this range, contact
MP Filtri Technical and Sales Department
Our Bell-Housings are available for anges standard
according to the SAE standard.
Note
The couplings GKS series are in conformity
to normative DIN 740/2.
Standard
- Fatigue test: 2 000 000 cycles
with nominal torque and frequency 10 Hz.
Bell-Housing
114
Hole
Hole
Pump
group
Pump group
Ø
Spigot hole
Ø
Spigot hole
A B
C
Ø2
Pump ange
code
Pump ange
code
Tapered
Key
Splined
Splined
Ø
Nr. of holes
Dimensions
Dimensions
Shaft type
Shaft type
LMEKENGINE VERSIONS FROM 10 TO 35 Hp
M6
M6
M8
M8
M10
M12
M16
FS100
FS1M0
FS200
FSZFR
S060
S070
S080
25.4
30
36.5
80
82.5
101.6
127
1
1
2
Bosh ZF
SAE A 2BOLT
SAE B 2BOLT
SAE C 2BOLT
26.2
24.5
32.5
34.5
72
73
96
100
85
56
71.5
72
106.4
146
181.2
1:8
1:8
1:8
1:5
9.7
12
17.2
16.9
2
2
2
2.4
3
3.2 - 4
3
-
-
9th 16/32 DP
9th 16/32 DP
9th 16/32 DP
13th 16/32 DP
14th 12/24 DP
Dimensions
Designation of pump ange and shaft
Ø Spigot hole
Ø2
Splined
prole
Hole
Ø Spigot hole
Hole
B
A
C
Splined
prole
key
Ø Spigot hole
Ø
Hole
B
A
C
Bell-Housing
115
0.5
Ø1
Weight
[kg]
Dimensions [mm]
67.5 92 110 78 8 3 8
Ø2 Ø3 Ø4
H1 H2 S F
99
LME 155xxM3
LME 155xx060
LME 155
Nr.4xF
pump centering ring
H1
H2
S
Ø1
Ø2
Ø3
Ø4
0.5
Ø1
Weight
[kg]
Dimensions [mm]
41.2 92 110 78 8 3 8
Ø2 Ø3 Ø4
H1 H2 S F
99
LME 155xxM3
LME 155xx060
LME 155
Nr.4xF
H1
H2
S
Ø1
Ø2
Ø3
Ø4
LME110T099FS100
LME110T099FS1M0
LME110T099FS100
LME110T099FS1M0
LME110T099FS100MM
LME110T099FS1M0MM
LME110T099FS100MM
LME110T099FS1M0MM
SGEA01C05056P10
SGEA01C05056P10
SGEA01G01056P10
SGEA01G01056P10
SGEA01C05056P10
SGEA01C05056P10
SGEA01G01056P10
SGEA01G01056P10
SGEA01FS100P10
SGEA01FS1M0P10
SGEA01FS100P10
SGEA01FS1M0P10
SGEA01FS100P10
SGEA01FS1M0P10
SGEA01FS100P10
SGEA01FS1M0P10
AKA110C05FS100P10
AKA110C05FS1M0P10
AKA110G01FS100P10
AKA110G01FS1M0P10
AKA110C05FS100P10MM
AKA110C05FS1M0P10MM
AKA110G01FS100P10MM
AKA110G01FS1M0P10MM
EGE0RR
EGE0RR
EGE0RR
EGE0RR
EGE0RR
EGE0RR
EGE0RR
EGE0RR
ANCA002
ANCA003
ANCA002
ANCA003
ANCA002
ANCA003
ANCA002
ANCA003
Power
Power
2.2-4
2.2-4
2.2-4
2.2-4
3-5.5
3-5.5
3-5.5
3-5.5
kW
kW
Hp
Hp
Shaft end
Shaft end
Pump
code
Pump
code
FS100
FS1M0
FS100
FS1M0
FS100
FS1M0
FS100
FS1M0
Ø 18 - Key 5
ISO 3019-2-E
Ø 18 - Key 5
ISO 3019-2-E
Ø 19.05 - Key 4.76
SAE straight shaft
Ø 19.05 - Key 4.76
SAE straight shaft
Bell-Housing code
Bell-Housing code
Spider
code
Spider
code
Spigot
hole
Spigot
hole
NOTE: Pump side centering rings are included in the bellhousing
Male centering ring Ø 41.2 - Gear pumps
Female centering Ø 67.5 - Gear pumps
LME
Dimensions
SG code
motor side
SG code
motor side
SG code
pump side
SG code
pump side
Complete
kit code
Complete
kit code
Combinations for Internal combustion engine 3 - 5.5 Hp
pump centering ring
Bell-Housing
116
LME 155xxM3
LME 155xx060
LME 155
LME 155xxM3
LME 155xx060
LME 155
1.0
Ø2Ø1
Weight
[kg]
Dimensions [mm]
127110 146 155 110 13 3 10
Ø3 Ø4 Ø5
H1 H2 S F
143
Nr.4xF
H1
H2
Ø1
Ø2
Ø3
Ø4
Ø5
Ø 25 - Key 7
ISO 3019-2-E
Ø 25 - Key 7
ISO 3019-2-E
Ø 25.4 - Key 6.35
SAE straight shaft
Combinations for internal combustion engine 7 - 18 Hp
Gear pumps
LME
Dimensions
LME155T140FS100
LME155T140FS1M0
LME155T140FS1M0
LME155T140FS200
LME155T140FS100
LME155T140FS1M0
LME155T140FS1M0
LME155T140FS200
SGEA21E06076P10
SGEA21E06076P10
SGEA21E06076P10
SGEA21E06076P10
SGEA21G040762FP10
SGEA21G040762FP10
SGEA21G040762FP10
SGEA21G040762FP10
SGEA21FS100P10
SGEA21FS1C0P10
SGEA21FS1M0P10
SGEA21FS200P10
AKA155E06FS100P10
AKA155E06FS1C0P10
AKA155E06FS1M0P10
AKA155E06FS200P10
SGEA21FS100P10
SGEA21FS1C0P10
SGEA21FS1M0P10
SGEA21FS200P10
AKA155G04FS100P10
AKA155 G04FS1C0P10
AKA155 G04FS1M0P10
AKA155 G04FS200P10
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
ANCC002
ANCC003
ANCC003
ANCC004
ANCC002
ANCC003
ANCC003
ANCC004
Power
5-13.5 7-18
kW Hp
Shaft end
Pump
code
FS100
FS1C0
FS1M0
FS200
FS100
FS1C0
FS1M0
FS200
Bell-Housing code
Spider
code
Spigot
hole
LME 155xxM3
LME 155xx060
LME 155
Nr.4xF
H1
H2
Ø1
Ø2
Ø3
Ø4
106.4
82.55
Ø5
1.0
Ø2Ø1
Weight
[kg]
Dimensions[mm]
127110 146 155 110 13 3 10
Ø3 Ø4 Ø5
H1 H2 S F
143
5-13.5 7-18
LME155T140S060
LME155T140S060
SGEA21E06076P10
SGEA21G040762FP10
SGEA21G01030P10
SGEA21G01030P10
AKG155E06SAEAP10
AKG155G04SAEAP10
EGE2RR
EGE2RR
-
-
Power
kW Hp
Shaft end
Pump
code
SAE A 2 BOLT
SAE A 2 BOLT
Bell-Housing
code
Spider
code
Spigot
hole
NOTE: Pump side centering rings are included in the bellhousing
Pump SAE A 2 BOLT
Nr.2 - M10
S
S
Ø 25.4 - Key 6.35
SAE straight shaft
pump centering ring
SG code
motor side
SG code
motor side
SG code
pump side
Complete
kit code
SG code
pump side
Complete
kit code
Bell-Housing
117
LME
Combinations for Internal combustion engine 7 - 18 Hp
Dimensions
Pump centering ring
Ø2
Ø1
Thickness
BELL-HOUSING MULTI- DRILLING
BELL-HOUSING MULTI-DRILLING FOR GROUP 1 AND 2
LME 155xxM3
LME 155xx060
LME 155
Nr.4xF
pump centering ring
H1
H2
Ø1
Ø2
Ø3
Ø4
Ø5
S
1.0
Ø2Ø1
Weight
[kg]
Dimensions [mm]
127110 146 155 110 13 3 10
Ø3 Ø4 Ø5
H1 H2 S F
143
LME155T140FS100M3
LME155T140FS100M3
LME155T140FS100M3
LME155T140FS100M3
LME155T140FS100M3
LME155T140FS100M3
LME155T140FS100M3
LME155T140FS100M3
SGEA21E06076P10
SGEA21E06076P10
SGEA21E06076P10
SGEA21E06076P10
SGEA21G040762FP10
SGEA21G040762FP10
SGEA21G040762FP10
SGEA21G040762FP10
SGEA21FS100P10
SGEA21FS1C0P10
SGEA21FS1M0P10
SGEA21FS200P10
SGEA21FS100P10
SGEA21FS1C0P10
SGEA21FS1M0P10
SGEA21FS200P10
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
EGE2RR
ANCC002
ANCC003
ANCC003
ANCC004
ANCC002
ANCC003
ANCC003
ANCC004
5-13.5 7-18
kW Hp
FS100 +
FS1C0 +
FS1M0 +
FS200
FS100 +
FS1C0 +
FS1M0 +
FS200
Gear pumps
Ø 25 - Key 7
ISO 3019-2-E
Ø 25.4 - Key 6.35
SAE straight shaft
Power
Shaft end
Pump
code
Bell-Housing code
Spider
code
Spigot hole
SG code
motor side
SG code
pump side
NOTE: Pump side centering rings are not included in the bellhousing
ANCA002
ANCA003
ANCC002
ANCC003
ANCC004
Ø1
Dimensions [mm]
Pump centering ring code
50
50
67.5
67.5
67.5
25.4
30.0
25.4
30.0
36.5
1.0
1.0
2.0
2.0
2.0
Ø2
Thickness
Bell-Housing
118
LME
Dimensions
Motor half-coupling
key 2 key
FG
Ø
Ø
Øe
key
Half-coupling for gear pumps
Weight
[kg]
Dimensions [mm]
40 10.0 17.0 7 2
40 - 17.0 12 3
65 14.5 21.5 12 3
SGEA01FS05CP10
SGEA01FS1C0P10
SGEA21FS1C0P10
0.08
0.13
0.48
Half-coupling code
L
L1
Øe
key
L
L1
Øe
L L1
Ø
Key
L
0.13
0.13
0.35
0.35
Dimensions [mm]
Half-coupling code Weight [kg]
SGEA01C05056P10
SGEA01G01056P10
SGEA21E06076P10
SGEA21G040762FP10
Øe
40
40
65
65
FG
M5
M5
M6
M6
L
56
56
76
76
Ø
18.00
19.05
25.00
25.40
Key
5.00
4.76
7.00
4.76
Key 2
6.00
-
-
6.35
NOTE: Double key version pump side only
Ø
Øe
Bell-Housing
119
Version for extreme temperatures available on request.
For further information, contact MP Filtri Technical and Sales Department.
Weight [kg] Tapered
Dimensions [mm]
40 14.5 16.0 9.7 2.4
40 16.0 16.0 13.9 3.0
65 14.5 21.5 9.7 2.4
65 18.5 21.5 13.9 3.0
65 21.5 21.5 17.2 3.2 - 4
SGEA01FS100P10
SGEA01FS1M0P10
SGEA21FS100P10
SGEA21FS1M0P10
SGEA21FS200P10
0.12
0.30
0.33
0.78
1.60
1:8
1:8
1:8
1:8
1:8
Half-coupling code
L
L1
Øe
key
Ø conn.
key
Øe
L L1
Ø
Key
Øe
Ø max
Ø max
Øe
15 40 16
18 65 25
0.006
0.02
Ø max
Weight [kg]
Dimensions [mm]
Half-coupling code
E
Øe
Code
15
115
30
230
E
SGEA01
SGEA21
EGE0RR
EGE2RR
Spider EGE**RR series
LME
Dimensions
Splined with key
Notes:
Made in polyurethane Laripur
LPR202-95A, red colour, are suitable
for applications where high levels
of torque are transmitted.
Nominal torque
Nm
Max torque
Nm
Half-coupling for gear pumps
Bell-Housing
120
LMEK 095
LMEK 100
LMEK 095
LMEK 100
LMEK
Dimensions
95
131
139
131
137 146
92.5
97
52
86
45
86
92.5
139
92.5
109
126
171
35
92.5
118
118
45
45
50
45
45
127
135
129
160
131
160
100
15
16
nr. 7 holes Ø9
nr. 11 holes Ø9
Kubota SUPER MINI
Kubota SERIES 05
1.7
2.5
Bell-Housing code
Bell-Housing code
Weight
[kg]
Weight
[kg]
Motor
series
Motor
series
LMEKSM095FS100
LMEKSM095FS1M0
LMEKSM095FS200
LMEKSM095FSZFR
LMEKSM095SAEA
LMEKSM095SAEA4B
LMEKSM095SAEB
LMEKSM095SAEB4B
LMEK05100FS100
LMEK05100FS1M0
LMEK05100FS200
LMEK05100FSZFR
LMEK05100SAEA
LMEK05100SAEA4B
LMEK05100SAEB
LMEK05100SAEB4B
LMEK05100SAEC
Kubota
SUPER MINI
Kubota
SERIES 05
LMEK - Bell-Housing for Kubota engines
Bell-Housing
121
GKS
Dimensions
GKSM SUPER MINI
Z482 - Z602 - Z722
GKSM SUPER MINI
D902
Ø115
Ø50
Ø150
Ø100
Ø130
60°
60°
36°
36°
2
27
H
Shaft type
nr. 8 holes
Ø8.5
Ø115
Ø50
Ø150
Ø100
Ø130
60°
60°
36°
36°
2
27
36
Shaft type
nr. 8 holes
Ø8.5
GKSMPB06
GKSMPB06
GKSMPB06D602
GKSMPB06
GKSMPD05
GKSMPD08
GKSMPB06D602
GKSMPB06D602
GKSMPB06D602
GKSMPB06D602
GKSMPD05
GKSMPD08
BCKFS100
BCKFS1M0
BCKFS200
BCKFSZFR
-
-
BCKFS100
BCKFS1M0
BCKFS200
BCKFSZFR
-
-
Motor
series
Motor
series
Material
Material
Tkn
[Nm]
Tkn
[Nm]
Tkm
[Nm]
Tkm
[Nm]
Tkp
[Nm]
Tkp
[Nm]
Max
RPM
Max
RPM
Drilling
code
Drilling
code
FS100
FS1M0
FS200
FSZFR
SAE A
SAE B
FS100
FS1M0
FS200
FSZFR
SAE A
SAE B
Kubota
Super
Mini
Z482
D602
D722
Kubota
Super
Mini
D902
NBR 70
Shore A
NBR 70
Shore A
100
100
196
196
296
296
0.5 mm
0.5 mm
6000
6000
0.95
0.95
1.5°
1.5°
Bushing
code
Bushing
code
Max disalligneament
Max disalligneament
angular
angular
radial
radial
Coupling
code
Coupling
code
Weight
[kg]
Weight
[kg]
1:8
1:8
1:8
1:5
-
-
41
41
36
41
36
36
1:8
1:8
1:8
1:5
-
-
-
-
-
-
9th 16/32 DP
13th 16/32 DP
-
-
-
-
9th 16/32 DP
13th 16/32 DP
Shaft
tapered
H
(mm)
Shaft
tapered
Shaft
splined
Shaft
splined
Coupling for Kubota motors
Bell-Housing
122
GKS / BCK
Dimensions
Ø115Ø50
Ø125
Ø100
60°
60°
2
27
41
Shaft
type
nr. 3 holes
Ø8.5
GKS5
SERIES 05
BCK
GKS5PB06
GKS5PB06
GKS5PB06
GKS5PB06
GKS5PD05
GKS5PD08
GKS5PD02
BCKFS100
BCKFS1M0
BCKFS200
BCKFSZFR
-
-
-
Motor
series
Material
Tkn
[Nm]
Tkm
[Nm]
Tkp
[Nm]
Max
RPM
Drilling
code
FS100
FS1M0
FS200
FSZFR
SAE A
SAE B
SAE C
Kubota
Series
05
NBR 70
Shore A
100 196 296 0.5 mm 6000 0.851.5°
Bushing
code
Max disalligneament
angularradial
Coupling
code
Weight
[kg]
1:8
1:8
1:8
1:5
-
-
-
-
-
-
-
9th 16/32 DP
13th 16/32 DP
14th 12/24 DP
Shaft
tapered
Shaft
splined
Key L
Pump group code Bushing code
Ø Conn.
Splined prole
DIN 5482B
No. teeth
Dimensions
2.4
3
3.2
3
14.5
16
22
20
BCKFS100
BCKFS1M0
BCKFS200
BCKFSZFR
FS100
FS1M0
FS200
FSZFR
8
12
14.2
13
1425x22
Shaft
tapered
1:8
1:8
1:8
1:5
Ø conn.
L
Splined prole
key
Bell-Housing
123
LMEK
LMEKSM095FS100
LMEKSM095FS1M0
LMEKSM095FS200
LMEKSM095FSZFR
LMEKSM095FS200
LMEKSM095FSZFR
LMEKSM095SAEA
LMEKSM095SAEB
LMEKSM095FS100
LMEKSM095FS1M0
LMEKSM095FS200
LMEKSM095FSZFR
LMEKSM095FS200
LMEKSM095FSZFR
LMEKSM095SAEA
LMEKSM095SAEB
LMEK05100FS100
LMEK05100FS1M0
LMEK05100FS200
LMEK05100FSZFR
LMEK05100FS200
LMEK05100FSZFR
LMEKSM095SAEA
LMEKSM095SAEB
LMEKSM095SAEC
AKALMEK095FS100BC
AKALMEK095FS1M0BC
AKALMEK095FS200BC
AKALMEK095FSZFRBC
AKALMEK095FS200PD05
AKALMEK095FSZFRPD05
AKALMEK095SAEAPD05
AKALMEK095SAEBPD08
AKALMEK095FS100BCD902
AKALMEK095FS1M0BCD902
AKALMEK095FS1M0BCD902
AKALMEK095FSZFRBCD902
AKALMEK095FS200PD05
AKALMEK095FSZFRPD05
AKALMEK095SAEAPD05
AKALMEK095SAEBPD08
AKALMEK100FS100BC
AKALMEK100FS1M0BC
AKALMEK100FS200BC
AKALMEK100FSZFRBC
AKALMEK100FS200PD05
AKALMEK100FSZFRPD05
AKALMEK100SAEAPD05
AKALMEK100SAEBPD08
AKALMEK100SAECPD02
BCKFS100
BCKFS1M0
BCKFS200
BCKFSZFR
-
-
-
-
BCKFS100
BCKFS1M0
BCKFS200
BCKFSZFR
-
-
-
-
BCKFS100
BCKFS1M0
BCKFS200
BCKFSZFR
-
-
-
-
-
GKSMPB06
GKSMPB06
GKSMPB06D602
GKSMPB06
GKSMPD05
GKSMPD05
GKSMPD05
GKSMPD08
GKSMPB06D602
GKSMPB06D602
GKSMPB06D602
GKSMPB06D602
GKSMPD05
GKSMPD05
GKSMPD05
GKSMPD08
GKS5PB06
GKS5PB06
GKS5PB06
GKS5PB06
GKS5PD05
GKS5PD05
GKS5PD05
GKS5PD08
GKS5PD02
Motor series
Motor series
Motor series
Pump code
Pump code
Pump code
FS100
FS1M0
FS200
FSZFR
FS200
FSZFR
SAE A
SAE B
FS100
FS1M0
FS200
FSZFR
FS200
FSZFR
SAE A
SAE B
FS100
FS1M0
FS200
FSZFR
FS200
FSZFR
SAE A
SAE B
SAE C
Kubota
Super Mini
Z482
D602
D722
Kubota
Super Mini
D902
Kubota
Series 05
Shaft type
Shaft type
Shaft type
Bushing code
Bushing code
Bushing code
Bell-housing code
Bell-housing code
Components
Components
Bell-housing code
Kit code
Kit code
Kit code
Coupling code
Coupling code
Coupling code
Tapered 1:8
Tapered 1:8
Tapered 1:8
Tapered 1:5
9th 16/32 DP
9th 16/32 DP
9th 16/32 DP
13th 16/32 DP
Tapered 1:8
Tapered 1:8
Tapered 1:8
Tapered 1:5
9th 16/32 DP
9th 16/32 DP
9th 16/32 DP
13th 16/32 DP
Tapered 1:8
Tapered 1:8
Tapered 1:8
Tapered 1:5
9th 16/32 DP
9th 16/32 DP
9th 16/32 DP
13th 16/32 DP
14th 12/24 DP
Components
Kubota Motors - Super Mini Z482 - D602 - D722
Kubota Motors - Super Mini D902
Kubota Motors - Series 05
TABLE OF COMBINATION
Bell-Housing
124
LME - LMEK
Super Mini series
Complete kit for Kubota motors
Series 05
Coupling type
Pump interface codes
BC
PD02
PD05
PD08
FS100
FS200
FS1MO
FSZFR
SAE A
SAE B
SAE C
Splined prole with bushing
Splined prole
Splined prole
Splined prole
Gr. 1
Gr. 1M
Gr. 2
Gr. ZF Bosh
2 BOLT
2 BOLT
2 BOLT
95
LMEK
100
COMPLETE KIT (BELL-HOUSING & COUPLINGS) FROM 13.5 TO 35 Hp
Bell-Housing
Kubota engine identication code
Conguration example:
AKALMEK FS100 BC
095
3 - 5.5 Hp
5.5 - 13.5 Hp
Pump interface codes
Shaft end codes
FS100
FS200
FS1M0
SAE A
C05
E06
G01
G04
Gr. 1
Gr. 2
Gr. 1M
2 BOLT
Ø18 -
Key
5
Ø25 -
Key
7
Ø19.05 -
Key
4.76
Ø25.4 -
Key
4.76 / 6.35
110
155
COMPLETE KIT (BELL-HOUSING & COUPLINGS) FROM 3 TO 13.5 Hp
Internal combustion engine identication code
Conguration example:
AKA155 FS200 P10
G04
Designation & Ordering code
Bell-Housing
125